Switch with extended stainless steel plunger.  Cat. no. LS-001 Switch with extended stainless steel plunger. Cat. no. LS-001
Suitable for use in Zone 1, (see below for contact arrangement), replaceable contact elements, positive opening contacts, dimensions and functional measurement to EN 50041

Explosion protection: EEx ed IIC T6, Ingress protection: IP65, Enclosure material: Polyamide, glass fibre reinforced, contact material: silver-nickel, Ambient temperature: -25 ºC .....+50ºC, Cable entries: 1 x M20 x 1.5




Switch with molded plastic roller plunger. Cat. no. LS-002
Suitable for use in Zone 1, (see below for contact arrangement), replaceable contact elements, positive opening contacts, dimensions and functional measurement to EN 50041

Explosion protection: EEx ed IIC T6, Ingress protection: IP65, Enclosure material: Polyamide, glass fibre reinforced, contact material: silver-nickel, Ambient temperature: -25 ºC .....+50ºC, Cable entries: 1 x M20 x 1.5



Switch with molded plastic roller plunger.  Cat. no. LS-002

Switch with moulded plastic roller lever, Form E.  Cat. no. LS-003 Switch with moulded plastic roller lever, Form E. Cat. no. LS-003
Suitable for use in Zone 1, (see below for contact arrangement), replaceable contact elements, positive opening contacts, dimensions and functional measurement to EN 50041

Explosion protection: EEx ed IIC T6, Ingress protection: IP65, Enclosure material: Polyamide, glass fibre reinforced, contact material: silver-nickel, Ambient temperature: -25 ºC .....+50ºC, Cable entries: 1 x M20 x 1.5




Switch with molded plastic roller lever for 0.3 Nm min. force. Cat. no. LS-004
Suitable for use in Zone 1, (see below for contact arrangement), replaceable contact elements, positive opening contacts, dimensions and functional measurement to EN 50041

Explosion protection: EEx ed IIC T6, Ingress protection: IP65, Enclosure material: Polyamide, glass fibre reinforced, contact material: silver-nickel, Ambient temperature: -25 ºC .....+50ºC, Cable entries: 1 x M20 x 1.5



Switch with molded plastic roller lever for 0.3 Nm min. force.  Cat. no. LS-004

Switch with molded plastic roller lever for 0.1 Nm min. force.  Cat. no. LS-005 Switch with molded plastic roller lever for 0.1 Nm min. force. Cat. no. LS-005
Suitable for use in Zone 1, (see below for contact arrangement), replaceable contact elements, positive opening contacts, dimensions and functional measurement to EN 50041

Explosion protection: EEx ed IIC T6, Ingress protection: IP65, Enclosure material: Polyamide, glass fibre reinforced, contact material: silver-nickel, Ambient temperature: -25 ºC .....+50ºC, Cable entries: 1 x M20 x 1.5




Switch with moulded plastic adjustable roller lever. Cat. no. LS-006
Suitable for use in Zone 1, (see below for contact arrangement), replaceable contact elements, positive opening contacts, dimensions and functional measurement to EN 50041

Explosion protection: EEx ed IIC T6, Ingress protection: IP65, Enclosure material: Polyamide, glass fibre reinforced, contact material: silver-nickel, Ambient temperature: -25 ºC .....+50ºC, Cable entries: 1 x M20 x 1.5



Switch with moulded plastic adjustable roller lever.  Cat. no. LS-006

Switch with stainless steel spring rod actuator.  Cat. no. LS-007 Switch with stainless steel spring rod actuator. Cat. no. LS-007
Suitable for use in Zone 1, (see below for contact arrangement), replaceable contact elements, dimensions and functional measurement to EN 5004. Not suitable for safety circuits

Explosion protection: EEx ed IIC T6, Ingress protection: IP65, Enclosure material: Polyamide, glass fibre reinforced, contact material: silver-nickel, Ambient temperature: -25 ºC .....+50ºC, Cable entries: 1 x M20 x 1.5




Switch with moulded plastic safety switch with seperate actuator. Cat. no. LS-008
Suitable for use in Zone 1, (see below for contact arrangement), replaceable contact elements, positive opening contacts, dimensions and functional measurement to EN 50041

Explosion protection: EEx ed IIC T6, Ingress protection: IP65, Enclosure material: Polyamide, glass fibre reinforced, contact material: silver-nickel, Ambient temperature: -25 ºC .....+50ºC, Cable entries: 1 x M20 x 1.5



Switch with moulded plastic safety switch with seperate actuator.  Cat. no. LS-008

Switch with moulded plastic actuating rod.  Cat. no. LS-009 Switch with moulded plastic actuating rod. Cat. no. LS-009
Suitable for use in Zone 1, (see below for contact arrangement), replaceable contact elements, positive opening contacts, dimensions and functional measurement to EN 50041

Explosion protection: EEx ed IIC T6, Ingress protection: IP65, Enclosure material: Polyamide, glass fibre reinforced, contact material: silver-nickel, Ambient temperature: -25 ºC .....+50ºC, Cable entries: 1 x M20 x 1.5