I.S. Palmtop.  Cat. no. HI-022 I.S. Palmtop. Cat. no. HI-022
Intrinsically safe stylish handheld PC with Palm OS 4.1. Approved for use in zone 1 or zone O hazardous areas, gas group IIC and temperature classification T4. An versatile device offering truly mobile computing with hazardous areas.

II 2 G EEx ia IIC T4 ZELM 02 ATEX 0086, Processor: Motorola Dragonball 33MHz, Memory: 16 MB RAM, Display: colour TFT, Illumination LED touch screen resolution 160 x 160, Interfaces: USB Hotsync, IrDA, Universal Palm, Power Supply: intergrated lithium-polymer accumulator,

Operating instructions and safety advice for hazardous areas, Supplied with carry case and USB Hotsync Docking Station. Dims: 114mm x 79mm x 18mm


I.S. Digital Dictation Unit Cat no. HI-021
Intrinsically safe hand portable dictation unit. Approved for use in zone 1 & 2 hazardous areas, gas group IIC and temperature classification T4. An extremely useful device for recording speech.

Ex II 2 G EEx ia IIC T4, 3 files A,B & S each with a storage capacity of 100 speech passages, Recording time 67 min (SP) or 180 min (LP), 16 Mb flash memory, diary function with appointment alarms, Rapid replay, ship advance, wake alarm, Active voice recording, Power supply 2 x LR03 type AAA batteries, Operating time approx 40 hrs, Dims 115mm x 48mm x 15mm

I.S. Digital Dictation Unit   Cat no. HI-021

I.S. Analogue/Digital Multimeter   Cat. no. HI-020 I.S. Analogue/Digital Multimeter Cat. no. HI-020
Intrinsically safe Hand held multimeter. Approved for use in zone 1 & 2 hazardous areas, gas group IIC and temperature classification T4. A high performance measuring device for both industrial and electronic applications.

Ex II 2 G EEx ia IIC T4 TUV 01 ATEX 1658 X, 11 functions (DC voltage, AC voltage, Direct current, Alternating current, Resistance, Contuctance, Continuity test, Diode test, Frequency, Duty cycle, Capacity), 4 1/2 digit display with bar indicator, distinct background lighting, Min/ max / avg. function, Splash proof with holster to IP44, Cat III 1000 volt as to EN 61010-1, Power supply 9V block to IEC 6LR61, Battery life approx 100 hrs, Dims 200mm x 98mm x 52mm.


I.S. Handheld PC with Windows CE software Cat. no. HI-018
Intrinsically safe compact handheld PC with Windows CE 3.0. Approved for use in zone 1 or zone O hazardous areas, gas group IIC and temperature classification T4. An extremely handy device offering the customary Windows and Office functions together with a wide range of options and applications on the move.

II 2 G EEx ia IIC T4 ZELM 02 ATEX 0084X, Processor: VP4122 150 MHz, Memory: 32 MB RAM, 16 MB F-ROM, Display: colour TFT, Illumination LED touch screen resolution 240 x 320, Interfaces: IrDA, (W-LAN option), Power Supply: rechargeable lithium-polymer accumulator, life approx 1000 charging cycles. Operating time: 10 hrs,

Operating instructions and safety advice for hazardous areas, Software: Microsoft Pocket Word, Pocket Excel, Pocket Outlook, Pocket EXploxer, Voice Recording, Image Editor and File Viewer. Supplied with carry case and battery charger. Dims: 195mm x 90mm x 40mm

I.S. Handheld PC with Windows CE software   Cat. no. HI-018

I.S. Hand Portable Radio   Cat. no. HI-019 I.S. Hand Portable Radio Cat. no. HI-019
Intrinsically safe Hand portable radio. Approved for use in zone 1 hazardous areas, gas group IIC and temperature classification T4. An extremely versatile device offering licience free (in many European countries) wireless communication.

Ex II 2 G EEx ia IIC T4, 8 channels, Illuminated display, 47 CTCSS and 83 DCS tones, Frequency range 446,00625 - 446,09375 MHz, S meter for optimal reception, Scanning function, channel spacing 12.5 KHz, Transmission power 500mW EIRP, Low Frequency output 0.5mW max. at 16 Ohm, Power supply Ni-MH storage battery, Operating time approx 7 -12 hrs,


I.S. Non Contact Temperature Meter Cat. no. HI-009
Intrinsically safe non contact temperature meter with laser sighting approved for use in zone 1 hazardous areas, gas group IIC and temperature classification T4. A highly reliable easy to use instrument for measuring the temperature of objects. Simply sight the object, press the trigger and read the temperature off the display.

II 2 G EEx ia IIC T4 TUV 00 ATEX 1597 X, Temperature range -30 deg C to +900 deg C, Accuracy -/+1 deg C or 1% of reading whichever is greater, Repeatability -/+1 deg C or 0.5% of reading whichever is greater, Display: minimum, maximum, graphical trend of last 10 readings, battery condition. Power supply: IEC LR6 / AA dims: 200mm x 170mm x 50mm

I.S. Non Contact Temperature Meter  Cat. no. HI-009

I.S. Non Contact Temperature Meter  Cat. no. HI-010 I.S. Non Contact Temperature Meter Cat. no. HI-010
Intrinsically safe non contact temperature meter with laser sighting approved for use in zone 1 hazardous areas, gas group IIC and temperature classification T4. A highly reliable easy to use instrument for measuring the temperature of objects. Simply sight the object, press the trigger and read the temperature off the display.

II 2 G EEx ia IIC T4 TUV 00 ATEX 1580 X, Temperature range -18 deg C to +260 deg C, Accuracy -/+2 deg C or 2% of reading whichever is greater, Repeatability -/+2 deg C or -/+ 2% of reading whichever is greater, Power supply: 9V alkaline battery dims: 152mm x 101mm x 38mm


I.S. Pressure Calibrator Cat. no. HI-004
Intrinsically safe pressure calibrator approved for use in zone hazardous areas, Gas group IIC, Temperature classification T4. Available in 3 configurations: I (Pneumatic calibrator) - range -800 mbar to +20 bar, II (Hydraulic calibrator) - range upto 400 bar, III (Without Pressure Generation) - for pressure reduction and controlled venting.

Explosion protection: Ex II 1 G EEx ia IIC T4, Working temperature range: -10 to +50 , Ingress protection: IP54, Large LCD Display, Power supply: 6 x LR14 batteries, Weight: 3kg

Complete with Batteries, carry case, connection leads / terminals & calibration certificate

I.S. Pressure Calibrator  Cat. no. HI-004

I.S. Continuity Tester  Cat. no. HI-005 I.S. Continuity Tester Cat. no. HI-005
Intrinsically safe continuity tester approved for use in hazardous areas, gas group IIC and temperature classification T4. The optical and acoustic indication allows for quick and easy testing of electrical circuits. The electronics are housed within the test probe, allowing both hands to be available to carry out the test work

Explosion protection: Ex II 2 G EEx ia IIC T4, Working temperature range: -20ºC to +50ºC, Visual readout: 4 x LED, Acoustoc readout: loudspeaker, Resistance range: 10 Ohm...450 Ohm, Power supply: 2 x LR03 batteries to IEC.

Applications include wiring checks, checking of electrical contacts, coil and transformer windings and establishing the forward direction of semiconductors,


I.S. Laser Pointer Cat. no. HI-001
An Intrinsically Safe laser pointer approved for use in zone hazardous areas, Gas group IIC, Temperature classification T4, Pocket-sized lightweight pointer for the illuminating or marking of moving parts without endangering personnel. An integral housing clip provides secure attachment to clothing.

Explosion protection: Ex II 2 G EEx ia IIC T4 & Ex II 2 D Ex iaD 21 T96ºC, Output: <1mW, Ambient Temperature range -10ºC to +40ºC, Power supply 2 x LR03 (AAA) micro batteries, 80 hours continuous operation, laser protection class 2

I.S. Laser Pointer  Cat. no. HI-001

I.S. Pocket Calculator  Cat. no. HI-002 I.S. Pocket Calculator Cat. no. HI-002
An Intrinsically Safe solar powered calculator approved for use in zone 1 hazardous areas, Gas group IIC, Temperature classification T4, Explosion protection: Ex II 2 G EEx ia IIC T4, Working temperature -10ºC to +40ºC.

Pocket-sized lightweight, provides 160 operations which are displayed to a maximum of 10 significant figures (plus 2 figure exponent). Solar panel power supply, Fixed physical constants: speed of light and electron charge, 160 mathematical functions


I.S. Magnet Probe Cat. no. HI-003
Intrinsically safe magnet probe approved for use in zone 1 hazardous areas, gas group IIC and temperature classification T6. Designed to detect alternating, direct or permanent magnetic fields within hazardous areas. Suitable for testing solenoid valves, relays, transformers and flow meters, connection to electronic circuitry or opening of terminal boxes is rendered unnecessary

Ex II 2 G EEx ia IIC T4, Ingress protection: IP654, Indication: built-in LED, Working temperature range: -20ºC to +50ºC, Automatic shut-off, Built-in magnet self test and battery check, Power supply: 2 x LR03 (AAA) batteries (replacement outside hazardous area),

I.S. Magnet Probe  Cat. no. HI-003

I.S. Multicalibrator   Cat. no. HI-006 I.S. Multicalibrator Cat. no. HI-006
Intrinsically safe multicalbrator approved for use in hazardous areas, Gas group IIC, Temperature classification T5. Versatile and compact design for the harshest environments with the highest level of accuracy and auto ranging as standard, this item means that on-site engineers can measure, calibrate, simulate and document not guess.

Explosion protection: Ex II 2 (1) G EEx ia IIC T5, Measuring/transmitting of mA, mV, V, T, PT thermoteres, ohm & frequency, Temperature units and scale: Units ºC and ºF, scales: IPT 68 & ITS 90 selectable, RS232 interface, optional 4MB memory card, 60 x 40 mm LCD display with 5 digit reading. Ambient temperature range: -10ºC to +50ºC, Power supply NIMH-Akku, Operating Time: 4h (measuring mode) & 2.5h transmitting mode.

Supplied complete with Carry case, connection leads, battery, charger & calibration certificate. Dims: 210mm x 120mm x 50m. Weight 1.2kgs




I.S. Field Calibrator Cat. no. HI-008
Intrinsically safe field calibrator approved for use in zone 1 hazardous areas, gas group IIC and temperature classification T6. An invaluable device ideally suited for inspecting, commissioning, maintenance and trouble-shooting on 0-20mA installations.

EEx ia IIC T6 PTB Nr. Ex-90.C.2011, Ingress protection to IP20, 3 operating modes: measuring, active (mA output) and passive (transmitter-simulator), Infinitely variable from 0-30mA (reliable for triggering of pre-alarms), Quick calibration of 4 to 20mA (fixed values). LCD display with polarity recognition, low battery charge, read output of the momentary current values, exceeding of maximum load. Power supply NiCd rechargeable battery (charging outside hazardous area only), Minimum of 3 hours continous operation at 20mA, dims: 180mm x 90mm x 35mm

I.S. Field Calibrator  Cat. no. HI-008