Atex Equipment Ltd
Tel. no. +44 1252 510550 - Fax. no. +44 1252 373596

Up Catalogue Info Search E Mail us

Online Catalogue : Intrinsically Safe Galvanic Isolators

SMART-Transmitter Power Supply, 1 Channel, Output 4...20mA. Cat no. GI-001
Smart Transmitter/Power Supply, 1 Channel, 24V d.c. SMART capable up to 12kHz (-1dB)

Explosion protection: EEx ia IIC, Nominal voltage DC 20V .... 35V, Power consumption 1.2W, Output signal 4 mA ... 20mA, Available voltage at 20mA 16.5V at 200 Ohm load, Ambient temperature -20 ºC .....+60ºC.

Suited for the following SMART systems: ABB, Chessel, Endress+Hauser, Eckhardt-Foxboro, Fisher-Rosemount, Fuji, Honeywell, Siemens, Smar, Yokogawa.

P&F part number: KFD2-STC1-Ex1

SMART-Transmitter Power Supply, 1 Channel, Output 4...20mA.  Cat no. GI-001

SMART-Transmitter Power Supply, 1 Channel, Output 1...5V.  Cat no. GI-002 SMART-Transmitter Power Supply, 1 Channel, Output 1...5V. Cat no. GI-002
Smart Transmitter/Power Supply, 1 Channel, 24V d.c. SMART capable up to 12kHz (-1dB)

Explosion protection: EEx ia IIC, Nominal voltage DC 20V .... 35V, Power consumption 1.2W, Output signal 1...5V, Available voltage at 20mA 15.8V, Ambient temperature -20 ºC .....+60ºC.

Suited for the following SMART systems: ABB, Chessel, Endress+Hauser, Eckhardt-Foxboro, Fisher-Rosemount, Fuji, Honeywell, Siemens, Smar, Yokogawa.

P&F part number: KFD2-STV1-Ex1-1


SMART-Transmitter Power Supply, 2 Channel, Output 4...20mA. Cat no. GI-003
Smart Transmitter/Power Supply, 2 Channel, 24V d.c. SMART capable up to 10kHz (-1dB)

Explosion protection: EEx ia IIC, Nominal voltage DC 20V .... 35V, Power consumption 2.5W, Output signal 4 mA ... 20mA, Available voltage at 20mA min.16V, Ambient temperature -20 ºC .....+60ºC

Suited for the following SMART systems: ABB, Endress+Hauser, Foxboro, Fisher-Rosemount, Fuji, Honeywell, Smar, Yokogawa.

P&F part number: KFD2-STC4-Ex2

SMART-Transmitter Power Supply, 2 Channel, Output 4...20mA.  Cat no. GI-003

SMART-Transmitter Power Supply, 1 Channel, Output 4...20mA.  Cat no. GI-004 SMART-Transmitter Power Supply, 1 Channel, Output 4...20mA. Cat no. GI-004
Smart Transmitter/Power Supply, 1 Channel, 24V d.c. SMART capable up to 40kHz (-1dB)

Explosion protection: EEx ia IIC, Nominal voltage DC 20V .... 35V, Power consumption 1.7W, Output signal 4 mA ... 20mA, Available voltage at 20mA 16.5V, Ambient temperature -20 ºC .....+60ºC.

Suited for the following SMART systems: ABB, Bailey, Chessel, Endress+Hauser, Eckhardt-Foxboro, Fisher-Rosemount, Fuji, Honeywell, Siemens, Smar, Yokogawa.

P&F part number: KFD2-STC3-Ex1


SMART-Transmitter Power Supply, 1 Channel, Output 1...5V. Cat no. GI-005
Smart Transmitter/Power Supply, 1 Channel, 24V d.c. SMART capable up to 40kHz (-1dB)

Explosion protection: EEx ia IIC, Nominal voltage DC 20V .... 35V, Power consumption 1.7W, Output signal 1 ...5V Available voltage at 20mA 16.5V, Ambient temperature -20 ºC .....+60ºC.

Suited for the following SMART systems: ABB, Bailey, Chessel, Endress+Hauser, Eckhardt-Foxboro, Fisher-Rosemount, Fuji, Honeywell, Siemens, Smar, Yokogawa.

P&F part number: KFD2-STV3-Ex1

SMART-Transmitter Power Supply, 1 Channel, Output 1...5V.  Cat no. GI-005

SMART-Transmitter Power Supply, 1 Channel, Output 2...10V.  Cat no. GI-006 SMART-Transmitter Power Supply, 1 Channel, Output 2...10V. Cat no. GI-006
Smart Transmitter/Power Supply, 1 Channel, 24V d.c. SMART capable up to 40kHz (-1dB)

Explosion protection: EEx ia IIC, Nominal voltage DC 20V .... 35V, Power consumption 1.7W, Output signal 2 ...10V Available voltage at 20mA 16.5V, Ambient temperature -20 ºC .....+60ºC.

Suited for the following SMART systems: ABB, Bailey, Chessel, Endress+Hauser, Eckhardt-Foxboro, Fisher-Rosemount, Fuji, Honeywell, Siemens, Smar, Yokogawa.

P&F part number: KFD2-STV3-Ex1-2


Universal Converter for RTDs and Thermocouples, Output 4...20mA Cat no. GI-007
Converter, 1 Channel, 24V d.c. Explosion protection: EEx ia IIC, Nominal voltage DC 20V .... 35V, Power consumption 1.5W, Output signal 4 ...20mA, Suitable for Pt 100, Ni 100 in 2,3 or 4 wire mode, Thermocouple type B,E,J,K,L,N,R,S or T (IEC 584) configured for programming jack, Free definable characteristic for resistance 0 Ohm....400 Ohm and voltage -50mV .... 150mV, Burnout monitoring for thermocouples, Ambient temperature -20 ºC .....+60ºC.

P&F part number: KFD2-UT-Ex1



Universal Converter for RTDs and Thermocouples, Output 4...20mA  Cat no. GI-007

Universal Converter for RTDs and Thermocouples, Output 1...5V  Cat no. GI-008 Universal Converter for RTDs and Thermocouples, Output 1...5V Cat no. GI-008
Converter, 1 Channel, 24V d.c. Explosion protection: EEx ia IIC, Nominal voltage DC 20V .... 35V, Power consumption 1.5W, Output signal 1....5V, Suitable for Pt 100, Ni 100 in 2,3 or 4 wire mode, Thermocouple type B,E,J,K,L,N,R,S or T (IEC 584) configured for programming jack, Free definable characteristic for resistance 0 Ohm....400 Ohm and voltage -50mV .... 150mV, Burnout monitoring for thermocouples, Ambient temperature -20 ºC .....+60ºC.

P&F part number: KFD2-UT-Ex1-1


Converter for RTDs, Output 0/4mA...20mA Cat no. GI-009
RTD Converter, 1 Channel, 24V d.c. Explosion protection: EEx ia IIC, Nominal voltage DC 20V .... 35V, Power consumption 1.2W, Current output 0/4....20mA (adjustable), Accuracy 0.1%, Adjustment options via DIP switch for temperature range, 2,3 or 4 wire configuration, sensor type and leak breakage monitoring. Suitable for use with models Pt 50, Pt100, Pt 500, Pt 1000, Ni 100, Ni 120, Ni 1000, D 100, PRC 100, F 130, Mo 1000 & Ohm, Ambient temperature -20 ºC .....+60ºC.

P&F part number: KFD2-TR-Ex1

Converter for RTDs, Output 0/4mA...20mA  Cat no. GI-009

Converter for Thermocouples Output 0/4mA...20mA  Cat no. GI-010 Converter for Thermocouples Output 0/4mA...20mA Cat no. GI-010
Thermocouple Converter, 1 Channel, 24V d.c. Explosion protection: EEx ia IIC, Nominal voltage DC 20V .... 35V, Power consumption 1.2W, Current output 0/4....20mA (adjustable), Accuracy +0.1%, Adjustment options via DIP switch for temperature range, thermocouple type, output 0 mA ... 20 mA & 4 mA .... 20 mA, leak breakage monitoring, optional cold junction compensation. Suitable for use with models type R,S,B,J,T,E & K. Ambient temperature -20 ºC .....+60ºC.

P&F part number: KFD2-TT-Ex1


Current/Voltage Repeater, 1 Channel, Output 4-20mA. Cat. no. GI-011
Current/Voltage Repeaterr, 1 Channel, 24V d.c. Explosion protection: EEx ia IIC, Nominal voltage DC 20V .... 35V, Maximum voltage 250v rms, Current max. of 20mA converted to voltage Voltage input range 0......10V. Adjustable "Zero Pointzero" accuracy +0.1%, Voltage drop 4V at 20mA, EMC in acc. with NAMUR NE21. Ambient temperature -20 ºC .....+60ºC.

P&F part number: KFD2-CD-Ex1.32

Current/Voltage Repeater, 1 Channel, Output 4-20mA.  Cat. no. GI-011

Smart Current/Voltage Repeater, 1 Channel, Output 0/4mA...20mA.  Cat.no. GI-012 Smart Current/Voltage Repeater, 1 Channel, Output 0/4mA...20mA. Cat.no. GI-012
SMART Current/Voltage Repeater, 1 Channel, 24V d.c. Explosion protection: EEx ib IIC, Nominal voltage DC 20V .... 32V, Maximum voltage DC 125V : AC 253V, Power consumption 1.2W, Available voltage at 20mA min. 14V, Load 700 Ohm. Accuracy 0.2%, Voltage drop at 20mA 1V terminals 9+ & 7- 6V terminals 8+ & 7-, EMC in acc. with NAMUR NE21. Ambient temperature -20 ºC .....+60ºC. Galvanic isolation suitable for HART communication

P&F part number: KFD2-SCD-Ex1.32


Transformer Isolated Barrier, 1 Channel with Relay Output, 24V dc. Cat.no. GI-013
Transformer Isolated Barrier, 1 Channel, 24V d.c. Explosion protection: EEx ia IIC, Nominal voltage DC 20V .... 30V, Rated voltage 8V, Shortcircuit current 8mA, Ambient temperature -20 ºC .....+60ºC.

P&F part number: KFD2-SR2-Ex1.W

Transformer Isolated Barrier, 1 Channel with Relay Output, 24V dc.  Cat.no. GI-013
Online Catalogue : Intrinsically Safe Galvanic Isolators

Up Catalogue Info Search E Mail us


Atex Equipment - heat tracing and hazardous area specialists