3BTV2 Self Regulating Heating Cable.  Cat. no. HC-001 3BTV2 Self regulating trace heating cable. Cat. no. HC-001
Self Regulating, parallel circuit trace heating cable for frost protection without steam cleaning. Twin 1.2mm2 copper conductors embedded in self regulating conductive core, modified polyolefin insulation, tinned copper braid, fluoropolymer (-CT) or polyolefin (-CR) outer jacket. Suitable for process temperature maintenance up to +65ºC

Certified Ex II 2 G Ex e II T6 & Ex II 2 D Ex tD A21 IP66 T80ºC for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (W/m 9 at 10 ºC)


5BTV2 Self regulating trace heating cable. Cat. no. HC-002
Self Regulating, parallel circuit trace heating cable for frost protection without steam cleaning. Twin 1.2mm2 copper conductors embedded in self regulating conductive core, modified polyolefin insulation, tinned copper braid, fluoropolymer (-CT) or polyolefin (-CR) outer jacket. Suitable for process temperature maintenance up to +65 ºC

Certified II 2 G EEx e(m) II T6 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (W/m 16 at 10 ºC)

5BTV2 Self Regulating Heating Cable.  Cat. no. HC-002

8BTV2 Self Regulating Heating Cable.  Cat. no. HC-003 8BTV2 Self regulating trace heating cable. Cat. no. HC-003
Self Regulating, parallel circuit trace heating cable for frost protection without steam cleaning. Twin 1.2mm2 copper conductors embedded in self regulating conductive core, modified polyolefin insulation, tinned copper braid, fluoropolymer (-CT) or polyolefin (-CR) outer jacket. Suitable for process temperature maintenance up to +65 ºC

Certified II 2 G EEx e(m) II T6 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (W/m 25 at 10 ºC)


10BTV2 Self regulating trace heating cable. Cat. no. HC-004
Self Regulating, parallel circuit trace heating cable for frost protection without steam cleaning. Twin 1.2mm2 copper conductors embedded in self regulating conductive core, modified polyolefin insulation, tinned copper braid, fluoropolymer (-CT) or polyolefin (-CR) outer jacket. Suitable for process temperature maintenance up to +65 ºC

Certified II 2 G EEx e(m) II T6 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (W/m 30 at 10 ºC)

10BTV2 Self Regulating Heating Cable.  Cat. no. HC-004

10QTVR2 Self Regulating Heating Cable.  Cat. no. HC-005 10QTVR2 Self regulating trace heating cable. Cat. no. HC-005
Self Regulating, parallel circuit trace heating cable for process temperature maintenance of pipes and vessels. Twin 1.4mm2 copper conductors embedded in self regulating conductive core, fluoropolymer insulation, tinned copper braid, fluoropolymer outer jacket. Suitable for process temperature maintenance up to +110 ºC which are not subject to steam cleaning

Certified II 2 G EEx e(m) II T4 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (W/m 38 at 10 ºC)


15QTVR2-CT Self regulating trace heating Cable. Cat. no. HC-006
Self Regulating, parallel circuit trace heating cable for process temperature maintenance of pipes and vessels. Twin 1.4mm2 copper conductors embedded in self regulating conductive core, fluoropolymer insulation, tinned copper braid, fluoropolymer outer jacket. Suitable for process temperature maintenance up to +110 ºC which are not subject to steam cleaning

Certified II 2 G EEx e(m) II T4 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (W/m 51 at 10 ºC)

15QTVR2-CT Self Regulating Heating Cable.  Cat. no. HC-006

20QTVR2-CT Self Regulating Heating Cable.  Cat. no. HC-007 20QTVR2-CT Self regulating trace heating cable. Cat. no. HC-007
Self Regulating, parallel circuit trace heating cable for process temperature maintenance of pipes and vessels. Twin 1.4mm2 copper conductors embedded in self regulating conductive core, fluoropolymer insulation, tinned copper braid, fluoropolymer outer jacket. Suitable for process temperature maintenance up to +110 ºC which are not subject to steam cleaning

Certified II 2 G EEx e(m) II T4 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (W/m 63 at 10 ºC)


4XTV2-CT-T3 Self regulating trace heating cable. Cat. no. HC-008
Self Regulating, parallel circuit trace heating cable for process temperature maintenance of pipes and vessels. Twin 2.3mm2 copper conductors separated by a spacer, coiled self regulating conductive fibres, high temperature fluoropolymer insulation, tinned copper braid, high temperature fluoropolymer outer jacket. Suitable for process temperature maintenance up to +120 ºC which may be subject to steam cleaning

Certified II 2 G EEx e(m) II 250 ºC (T2)/T3/ T4 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (W/m 12 at 10 ºC)

4XTV2-CT-T3 Self Regulating Heating Cable.  Cat. no. HC-008

8XTV2-CT-T3 Self Regulating Heating Cable.  Cat. no. HC-009 8XTV2-CT-T3 Self regulating trace heating cable. Cat. no. HC-009
Self Regulating, parallel circuit trace heating cable for process temperature maintenance of pipes and vessels. Twin 2.3mm2 copper conductors separated by a spacer, coiled self regulating conductive fibres, high temperature fluoropolymer insulation, tinned copper braid, high temperature fluoropolymer outer jacket. Suitable for process temperature maintenance up to +120 ºC which may be subject to steam cleaning

Certified II 2 G EEx e(m) II 250 ºC (T2)/T3/ T4 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (W/m 25 at 10 ºC)


12XTV2-CT-T3 Self regulating trace heating cable. Cat. no. HC-010
Self Regulating, parallel circuit trace heating cable for process temperature maintenance of pipes and vessels. Twin 2.3mm2 copper conductors separated by a spacer, coiled self regulating conductive fibres, high temperature fluoropolymer insulation, tinned copper braid, high temperature fluoropolymer outer jacket. Suitable for process temperature maintenance up to +120 ºC which may be subject to steam cleaning

Certified II 2 G EEx e(m) II 250 ºC (T2)/T3/ T4 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (38 W/m at 10 ºC)

12XTV2-CT-T3 Self Regulating Heating Cable.  Cat. no. HC-010

15XTV2-CT-T3 Self Regulating Heating Cable.  Cat. no. HC-011 15XTV2-CT-T3 Self regulating trace heating cable. Cat. no. HC-011
Self Regulating, parallel circuit trace heating cable for process temperature maintenance of pipes and vessels. Twin 2.3mm2 copper conductors separated by a spacer, coiled self regulating conductive fibres, high temperature fluoropolymer insulation, tinned copper braid, high temperature fluoropolymer outer jacket. Suitable for process temperature maintenance up to +120 ºC which may be subject to steam cleaning

Certified II 2 G EEx e(m) II 250 ºC (T2)/T3/ T4 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (47 W/m at 10 ºC)


20XTV2-CT-T2 Self regulating trace heating Cable. Cat. no. HC-012
Self Regulating, parallel circuit trace heating cable for process temperature maintenance of pipes and vessels. Twin 2.3mm2 copper conductors separated by a spacer, coiled self regulating conductive fibres, high temperature fluoropolymer insulation, tinned copper braid, high temperature fluoropolymer outer jacket. Suitable for process temperature maintenance up to +120 ºC which may be subject to steam cleaning

Certified II 2 G EEx e(m) II 250 ºC (T2)/T3/ T4 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (63 W/m at 10 ºC)

20XTV2-CT-T2 Self Regulating Heating Cable.  Cat. no. HC-012

5KTV2-CT Self Regulating Heating Cable.  Cat. no. HC-013 5KTV2-CT Self regulating trace heating cable. Cat. no. HC-013
Self Regulating, parallel circuit trace heating cable for process temperature maintenance of pipes and vessels. Twin 2.3mm2 copper conductors separated by a spacer, coiled self regulating conductive fibres, high temperature fluoropolymer insulation, tinned copper braid, high temperature fluoropolymer outer jacket. Suitable for process temperature maintenance up to +150 ºC which may be subject to steam cleaning

Certified II 2 G EEx e(m) II 226 ºC (T2)/T3/ T4 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (16 W/m at 10 ºC)


8KTV2-CT Self regulating trace heating cable. Cat. no. HC-014
Self Regulating, parallel circuit trace heating cable for process temperature maintenance of pipes and vessels. Twin 2.3mm2 copper conductors separated by a spacer, coiled self regulating conductive fibres, high temperature fluoropolymer insulation, tinned copper braid, high temperature fluoropolymer outer jacket. Suitable for process temperature maintenance up to +150 ºC which may be subject to steam cleaning

Certified II 2 G EEx e(m) II 226 ºC (T2)/T3/ T4 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (25 W/m at 10 ºC)

8KTV2-CT Self Regulating Heating Cable.  Cat. no. HC-014

15KTV2-CT Self Regulating Heating Cable.  Cat. no. HC-015 15KTV2-CT Self regulating heating cable. Cat. no. HC-015
Self Regulating, parallel circuit trace heating cable for process temperature maintenance of pipes and vessels. Twin 2.3mm2 copper conductors separated by a spacer, coiled self regulating conductive fibres, high temperature fluoropolymer insulation, tinned copper braid, high temperature fluoropolymer outer jacket. Suitable for process temperature maintenance up to +150 ºC which may be subject to steam cleaning

Certified II 2 G EEx e(m) II 226 ºC (T2)/T3/ T4 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (47 W/m at 10 ºC)


20KTV2-CT Self regulating trace heating cable. Cat. no. HC-016
Self Regulating, parallel circuit trace heating cable for process temperature maintenance of pipes and vessels. Twin 2.3mm2 copper conductors separated by a spacer, coiled self regulating conductive fibres, high temperature fluoropolymer insulation, tinned copper braid, high temperature fluoropolymer outer jacket. Suitable for process temperature maintenance up to +150 ºC which may be subject to steam cleaning

Certified II 2 G EEx e(m) II 226 ºC (T2)/T3/ T4 for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V. Power Output (65 W/m at 10 ºC)

20KTV2-CT Self Regulating Heating Cable.  Cat. no. HC-016

5VPL2-CT High Temp. Power Limiting Heating Cable.  Cat. no. HC-017 5VPL2-CT High temperature. Power limiting trace heating cable. Cat. no. HC-017
Power limiting trace heating cable for frost protection and process temperature maintenance requiring high power output and/or high temperature exposure. Twin 3.3mm2 nickel plated copper conductors individually sheathed with high temperature fluoropolymer conductor insulation, covered with clear jacket and coiled power limiting heating element, high temperature fluoropolymer inner jacket, metal braid, high temperature fluoropolymer outer jacket. Suitable for process temperature maintenance up to +150 ºC which can withstand routine steam purges and temperature exposure to 250 ºC with power off.

Certified Ex II 2GD & Exe II T*(by design) Ex tD A21 IP66* for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V.

Power Output (15 W/m at 10 ºC)


10VPL2-CT High temperture. Power limiting trace heating cable. Cat. no. HC-018
Power limiting trace heating cable for frost protection and process temperature maintenance requiring high power output and/or high temperature exposure. Twin 3.3mm2 nickel plated copper conductors individually sheathed with high temperature fluoropolymer conductor insulation, covered with clear jacket and coiled power limiting heating element, high temperature fluoropolymer inner jacket, metal braid, high temperature fluoropolymer outer jacket. Suitable for process temperature maintenance up to +150 ºC which can withstand routine steam purges and temperature exposure to 250 ºC with power off.

Certified Ex II 2GD & Exe II T*(by design) Ex tD A21 IP66* for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V.

Power Output (30 W/m at 10 ºC)

10VPL2-CT High temperature. Power Limiting Heating Cable.  Cat. no. HC-018

15VPL2-CT High Temp. Power Limiting Heating Cable.  Cat. no. HC-019 15VPL2-CT High Temp. Power limiting heating cable. Cat. no. HC-019
Power limiting trace heating cable for frost protection and process temperature maintenance requiring high power output and/or high temperature exposure. Twin 3.3mm2 nickel plated copper conductors individually sheathed with high temperature fluoropolymer conductor insulation, covered with clear jacket and coiled power limiting heating element, high temperature fluoropolymer inner jacket, metal braid, high temperature fluoropolymer outer jacket. Suitable for process temperature maintenance up to +150 ºC which can withstand routine steam purges and temperature exposure to 250 ºC with power off.

Certified Ex II 2GD & Exe II T*(by design) Ex tD A21 IP66* for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V.

Power Output (45 W/m at 10 ºC)


20VPL2-CT High Temp. Power limiting heating cable. Cat. no. HC-020
Power limiting trace heating cable for frost protection and process temperature maintenance requiring high power output and/or high temperature exposure. Twin 3.3mm2 nickel plated copper conductors individually sheathed with high temperature fluoropolymer conductor insulation, covered with clear jacket and coiled power limiting heating element, high temperature fluoropolymer inner jacket, metal braid, high temperature fluoropolymer outer jacket. Suitable for process temperature maintenance up to +150 ºC which can withstand routine steam purges and temperature exposure to 250 ºC with power off.

Certified Ex II 2GD & Exe II T*(by design) Ex tD A21 IP66* for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V.

Power Output (60 W/m at 10 ºC)

20VPL2-CT High temperature. Power Limiting Heating Cable.  Cat. no. HC-020

IHT/2/10-CT Constant Wattage Heating Cable  Cat. no. HC-021 IHT/2/10-CT Constant wattage trace heating cable Cat. no. HC-021
Parallel circuit, medium powered constant output trace heating cable for high temperature process maintenance applications in chemically aggressive environments. Also suitable for freeze protection and heating of pipelines, valves, pumps and containers. Twin 1.5mm2 conductors individually sheathed with high quality Teflon FEP primary and inner insulation, the heating element is zone connected to bus wires covered with Teflon FEP outer insulation jacket, tinned copper braid, Teflon FEP outer jacket. Suitable to withstand temperatures up to +200 ºC (de-energised) and 125 ºC (energised).

Area classification NON HAZARDOUS. Supply voltage 220-240V.

Nominal Power Output (10/12 W/m at 10 ºC ). Max cicuit length 120 m


IHT/2/20-CT Constant Wattage Heating Cable Cat. no. HC-022
Parallel circuit, medium powered constant output heating cable for high temperature process maintenance applications in chemically aggressive environments. Also suitable for freeze protection and heating of pipelines, valves, pumps and containers. Twin 1.5mm2 conductors individually sheathed with high quality Teflon FEP primary and inner insulation, the heating element is zone connected to bus wires covered with Teflon FEP outer insulation jacket, tinned copper braid, Teflon FEP outer jacket. Suitable to withstand temperatures up to +200 ºC (de-energised) and 100 ºC (energised).

Area classification NON HAZARDOUS. Supply voltage 220-240V.

Nominal Power Output (20/24 W/m at 10 ºC) Max circuit length 90 m

IHT/2/20-CT Constant Wattage Heating Cable  Cat. no. HC-022

IHT/2/30-CT Constant Wattage Heating Cable  Cat. no. HC-023 IHT/2/30-CT Constant wattage trace heating cable Cat. no. HC-023
Parallel circuit, medium powered constant output trace heating cable for high temperature process maintenance applications in chemically aggressive environments. Also suitable for freeze protection and heating of pipelines, valves, pumps and containers. Twin 1.5mm2 conductors individually sheathed with high quality Teflon FEP primary and inner insulation, the heating element is zone connected to bus wires covered with Teflon FEP outer insulation jacket, tinned copper braid, Teflon FEP outer jacket. Suitable to withstand temperatures up to +200 ºC (de-energised) and 75 ºC (energised).

Area classification NON HAZARDOUS. Supply voltage 220-240V.

Nominal Power Output (30/36 W/m at 10 ºC) Max circuit length 75 m


FHT/2/10-CT Constant wattage trace heating cable Cat. no. HC-024
Constant wattage parallel circuit trace heating cable for frost protection and process temperature maintenance requiring high power output and/or high temperature exposure. The heating element is wrapped around twin 1.5mm2 conductors individually sheathed in PTFEconductor insulation, PTFE insulation stranding, covered with PTFE insulation tape and clear PFA insulation, nickel-plated copper braid, PTFE insulation tape and PFA outer jacket. Suitable for process temperature maintenance up to +150 ºC which can withstand routine steam purges and temperature exposure to 260 ºC with power off.

Certified II 2 G EEx e II T6 to 230 ºC (T2) for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V.

Nominal Power Output (10 W/m at 10 ºC) Max circuit length 200 m

FHT/2/10-CT Constant Wattage Heating Cable  Cat. no. HC-024

FHT/2/20-CT Constant Wattage Heating Cable  Cat. no. HC-025 FHT/2/20-CT Constant wattage trace heating cable. Cat. no. HC-025
Constant wattage parallel circuit heating cable for frost protection and process temperature maintenance requiring high power output and/or high temperature exposure. The heating element is wrapped around twin 1.5mm2 conductors individually sheathed in PTFEconductor insulation, PTFE insulation stranding, covered with PTFE insulation tape and clear PFA insulation, nickel-plated copper braid, PTFE insulation tape and PFA outer jacket. Suitable for process temperature maintenance up to +150 ºC which can withstand routine steam purges and temperature exposure to 260 ºC with power off.

Certified II 2 G EEx e II T6 to 230 ºC (T2) for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V.

Nominal Power Output (20 W/m at ºC) Max circuit length 150 m


FHT/2/30-CT Constant wattage trace heating cable. Cat. no. HC-026
Constant wattage parallel circuit heating cable for frost protection and process temperature maintenance requiring high power output and/or high temperature exposure. The heating element is wrapped around twin 1.5mm2 conductors individually sheathed in PTFEconductor insulation, PTFE insulation stranding, covered with PTFE insulation tape and clear PFA insulation, nickel-plated copper braid, PTFE insulation tape and PFA outer jacket. Suitable for process temperature maintenance up to +150 ºC which can withstand routine steam purges and temperature exposure to 260 ºC with power off.

Certified II 2 G EEx e II T6 to 230 ºC (T2) for use in zone 1 or zone 2 hazardous areas. Supply voltage 230V.

Nominal Power Output (30 W/m at ºC) Max circuit length 120 m

FHT/2/30-CT Constant Wattage Heating Cable  Cat. no. HC-026

FG220-10 Constant Wattage Heating Cable  Cat. no. HC-027 FG220-10 Constant wattage trace heating cable Cat. no. HC-027
Parallel circuit, medium powered constant output trace heating cable for high temperature process maintenance applications in nonchemically aggressive environments. Twin 1.1mm2 conductors sheathed with high quality silicone rubber, wrapped zone connected heating element covered with secondary silicone rubber insulation jacket. (Optional stainless steel braid available). Suitable to withstand temperatures up to +220 ºC (de-energised) and 165 ºC (energised).

Area classification NON HAZARDOUS. Supply voltage 230-110V.

Nominal Power Output 10 W/m at 10 ºC. Max cicuit length 160 m (230V) 80m (110V)


FG220-20 Constant wattage trace heating cable. Cat. no. HC-028
Parallel circuit, medium powered constant output trace heating cable for high temperature process maintenance applications in nonchemically aggressive environments. Twin 1.1mm2 conductors sheathed with high quality silicone rubber, wrapped zone connected heating element covered with secondary silicone rubber insulation jacket. (Optional stainless steel braid available). Suitable to withstand temperatures up to +220 ºC (de-energised) and 150 ºC (energised).

Area classification NON HAZARDOUS. Supply voltage 230-110V.

Nominal Power Output 20 W/m at 10ºC. Max cicuit length 100 m (230V) 50m (110V)

FG220-20 Constant Wattage Heating Cable  Cat. no. HC-028

FG220-30 Constant Wattage Heating Cable  Cat. no. HC-029 FG220-30 Constant Wattage Heating Cable Cat. no. HC-029
Parallel circuit, medium powered constant output heating cable for high temperature process maintenance applications in nonchemically aggressive environments. Twin 1.1mm2 conductors sheathed with high quality silicone rubber, wrapped zone connected heating element covered with secondary silicone rubber insulation jacket. (Optional stainless steel braid available). Suitable to withstand temperatures up to +220 ºC (de-energised) and 135 ºC (energised).

Area classification NON HAZARDOUS. Supply voltage 230-110V.

Nominal Power Output 30 W/m at ºC. Max cicuit length 90 m (230V) 40m (110V)


FG260-40 Constant wattage trace heating Cable Cat. no. HC-030
Parallel circuit, medium powered constant output trace heating cable for high temperature process maintenance applications in nonchemically aggressive environments. Twin 1.1mm2 conductors sheathed with high quality silicone rubber, wrapped zone connected heating element covered with secondary silicone rubber insulation jacket. (Optional stainless steel braid available). Suitable to withstand temperatures up to +260 ºC (de-energised) and 185 ºC (energised).

Area classification NON HAZARDOUS. Supply voltage 230V.

Nominal Power Output 40 W/m at 10 ºC. Max cicuit length 60 m (230V) Not available (110V)